Skip to main content

CONCRETE PLACEMENT

We manage the full chain, from mix design to final report.

Structural concrete across large-scale industrial, commercial and social infrastructure in New South Wales and Queensland.

The Work Starts Before the Pour

The quality of a placement is determined well before the truck arrives. Mix design, plant setup, crew briefing and site-specific risk assessment all happen before work begins. By the time a pour starts, there are no open questions.

Our in-house technical concrete team develops mix specifications for each project environment and works directly with suppliers to lock in material quality and programme reliability. That is the part most concrete subcontractors leave to someone else, and it is the part that fails first.

OUR METHOD

MIX DESIGN

The mix is developed for the element, the finish and the season; it is not accepted as delivered. Slump, aggregate, admixture and strength gain are all matched to the job in front of us. A mix that performs in April behaves differently in January, and the difference shows up in the finish.

SEQUENCING & PLANNING

Every pour is a document before it is a day’s work. Pour sizes, joint locations, truck sequencing, pump positions, standby plant, crew numbers, weather contingency and the stop point if supply fails. Wind, rain and heat all change how a pour runs, so the forecast is one of the first things checked on a pour day.

THE POUR

Placement rate is matched to crew capacity so concrete is never sitting waiting to be worked. Our supervisors run the deck, and they have the authority to stop.

FINISH

From broom and trowel through to burnished, off-form architectural and waterglass finishes. The power float window is measured in minutes. Getting it right is the difference between a floor that lasts and a floor that gets ground.

TOLERANCES

Where a project specifies flatness and levelness, we measure and record rather than assume. Dipstick measurement runs through placement, not as a check at the end.

CURING

Curing is where a good pour is most often lost. Method, duration and protection are specified per element and per season, and we do not release a slab because the programme wants it.

documentation

Inspection and Test Plans, test results, pour records, survey data and conformance reports are compiled progressively. Post-pour reporting, inspection sign-off and non-conformance resolution are part of the delivery, not an afterthought. Our clients receive complete documentation without having to request it.

THE PLANT BEHIND IT

We own the equipment that makes the method possible, which means the programme is ours to control rather than something we hire in and hope for.

  • 11 Concrete pumps, booms, lines, and trailers.
  • 13 Tower and spider booms.
  • 8 Somero laser screeds and Line Dragons.
  • 30 Ride-on trowel machines.
  • 40 Walk-behind trowel machines.

Tower booms, spider booms on jump form and all-electric pumps let us reach the upper levels of a tower or hold a rate across a 50,000 m² floor. Both are placement problems. They need different answers.

WHEN SOMETHING
GOES WRONG

Concrete is a live product, and occasionally a pour does not go to plan. What separates contractors is what happens next.

Progress, issues, variations and programme impacts are flagged as they arise, not at the end of a week when the options have narrowed. Our clients should never have to follow up to find out where a job stands.

BUILD WITH US.

Good people built this business. We are always looking for more.
LET’S TALK

NEED TO REACH US?